Page 79 - Lockwell Industrial Catalogue
P. 79

 380/480 Vac ±10%
Finger-guard grommet Frame size
9A / 9E
Option modules
(available from frame size 2 and upwards)
SI-EtherCAT SI-PROFIBUS SI-Ethernet SI-DeviceNet SI-CANopen SI-PROFINET SI-I/O
Lifting tool Frame size
9A 9E
Fan replacement kit Frame size
Order Code
Cx00-024 00013A Cx00-024 00018A Cx00-024 00023A Cx00-024 00032A Cx00-024 00041A Cx00-034 00056A Cx00-034 00073A Cx00-034 00094A Cx00-044 00135A Cx00-044 00170A Cx00-054 00270A Cx00-054 00300A Cx00-06400350A Cx00-064 00420A Cx00-064 00470A Cx00-074 00660A Cx00-074 00770A Cx00-074 01000A Cx00-084 01340A Cx00-084 01570A Cx00-094 02000A Cx00-094 02240A Cx00-094 02000E Cx00-094 02240E
Optional keypad
Remote Keypad Remote keypad RTC
Optional accessories
AI-Back-up Adaptor AI-485 Adaptor AI-Smart Adaptor
RS485 cable AI-485 24 V Adaptor
Through hole IP65 kit* Frame size
5 6 7 8 9A 9E
Line reactor Frame size
9E (400 V)
Supply Phases
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
Max Cont. Current (A)
Max Cont. Current (A)
Motor Power (kW)
Motor Power (HP)
Heavy Duty
Motor Motor Power Power (kW) (HP)
1.3
1.8
2.3
3.2
4.1
5.6
7.3 3 3 9.4 4 5
Normal Duty
Order code
3470-0107
Order code
82400000018000 82400000017500 82400000017900 82400000017700 82400000017600 82400000018200 82400000017800
Order code
7778-0045 7778-0016
Order code
3470-0092 3470-0095 3470-0099 3470-0103
13.5 17 27 30 35 42 47 66 77 100 134 157 200 224 200 224
Order code
82500000000001 82400000019600
Order code
82500000000004 82500000000003 82500000018500 4500-0096 82500000019700
Order code
3470-0067 3470-0055 3470-0079 3470-0083 3470-0119 3470-0105
Order code
7022-0063
5.5 7.5 7.5 10 11 20 15 20 15 25 18.5 30 22 30 30 50 37 60 45 75
55 100 75 125 90 150 110 150 90 150 110 150
112 155 184 221 266 221 266
55
75
90
110 150 Frame
132 200 size
1 2 3 4
Can't see what you need? Our experts can help!
DRIVE SPECIALISTS SINCE 1973 13 79
0.37 0.5 0.55 0.75 0.75 1
1.1 1.5 1.5 2 2.2 3
For Normal Duty applications, use Heavy Duty ratings.
30 15 20 31 15 20 38 18.5 25 48 22 30 63 30 50 79 37 60 94 45 75
DRIVES & STARTERS
UL Type 1 Conduit kit Frame size
1
2
3
4
5
6
7
8 / 9A 9E
3470-0091 2 3470-0094
3470-0098
3470-0102
3470-0069
3470-0059
3470-0080
3470-0088 3 3470-0115
110 150 132 200
Order code
1
Voltage
All
All 100 V
200 V
400 V
200 V
400 V
200 V
400 V
200 V 400 V 200 V 400 V
Phases
1 1
1 1 1 3 3 3 3 1 1 3 3 3 3 1 1 3 3 3 3 3 3 3 3 3 3 3
Type
Standard Low leakage Standard Standard Low leakage Standard Low leakage Standard Low leakage Standard Low leakage Standard Low leakage Standard Low leakage Standard Low leakage Standard Low leakage Standard Low leakage Standard Standard Standard Standard Standard Standard Standard
Order code
4200-1000 4200-1001
4200-2000 4200-2001 4200-2002 4200-2003 4200-2004 4200-2005 4200-2006 4200-3000 4200-3001 4200-3004 4200-3005 4200-3008 4200-3009 4200-4000 4200-4001 4200-4002 4200-4003 4200-4004 4200-4005 4200-0312 4200-0402 4200-2300 4200-4800 4200-1132 4200-1972 4200-3021
Retrofit mounting brackets** Frame size
3
4
5 3470-0066 4
6 3470-0074
7 3470-0078
8 3470-0087
9A / 9E 3470-0118
5 of the drive when through panel mounted using 6
*IP65 / UL TYPE 12 rating is achieved on the rear
Order code
3470-0097 3470-0101
the following kits.
**These mounting brackets ensure the drive can be
mounted on existing Commander SK installations. 8
9 200 V & 400V
75 100 125
Optional external EMC filters ◆
7 200 V & 400V
200 V & 400V
◆ Commander C built-in EMC filter complies with EN/IEC 61800-3. External EMC filters are required for compliance with EN/IEC 61000-6-4 as per the table below.
   77   78   79   80   81