Page 78 - Lockwell Industrial Catalogue
P. 78

                                           COMMANDER C
Drive Selection and Order Information
How to select a drive
Electrical Considerations
◼ What is the supply voltage?
◼ Single or 3Ø input power?
◼ What is the motor rating?
◼ Continuous current – FLA (Full Load Amps)
◼ Select the drive based on motor Amps rather than horsepower
Drive Mechanical Mounting
◼ Panel mounting – as standard ◼ Wall mounting – UL conduit kits
are available
◼ Through panel mounting – frames 5 and up
Frame size
1
2
3 4 5 6 7 8 9E
Dimensions
H x W x D mm (in)
160 x 75 x 130 (6.3 x 2.95 x 5.1)
205 x 75 x 150 (8.07 x 2.95 x 5.9)
226 x 90 x 160 (8.9 x 3.54 x 6.3)
277 x 115 x 175 (10.9 x 4.5 x 6.9)
391 x 143 x 200 (15.39 x 5.63 x 7.87)
391 x 210 x 227 (15.39 x 8.27 x 8.94)
557 x 270 x 280 (21.93 x 10.63 x 11.02)
804 x 310 x 290 (31.65 x 12.21 x 11.42)
1069 x 310 x 290 (42.09 x 12.21 x 11.42)
1108 x 310 x 290 (43.62 x 12.21 x 11.42)
Weight kg (lb)
0.75 (1.65)
1.3 (3.0)
1.5 (3.3)
3.13 (6.9)
7.4 (16.3)
14 (30.9)
28 (61.70)
52 (114.6)
46 (101.4)
66.5 (146.6)
                     Key:
Derivative
CX00-
Variant C200 or C300
W
                   Frame & Volts
Current
00073
Current Rating (A): Heavy Duty Rating x 10
1.7 2.4 3.3 4.2 2.4 3.3 4.2 5.6 7.5 10 13.3 17.6 25 33 44 61 75 83 116 132 176 219 176 219
For Normal Duty applications, use Heavy Duty ratings.
30 7.5 10 50 11 15 58 15 20 75 18.5 25 94 22 30 117 30 40 149 37 50 180 45 60 216 55 75 266 75 100 216 55 75 266 75 100
Drive format
           03
Frame Size
4
A
H
               Voltage Rating: 1 - 100 V, 2 - 200 V, 4 - 400 V
A - Internal Line Choke
E - External Line Choke Required
D 9A
                      100/120 Vac ±10%
     Order Code
Cx00-011 00017A Cx00-011 00024A Cx00-021 00042A Cx00-021 00056A
200/240 Vac ±10%
Heavy Duty Motor Power (kW)
1
1
1 4.2 0.75 1
Normal Duty Motor Power (kW)
Supply Phases
Max Cont.Current (A)
Motor Power (HP)
Max Cont.Current (A)
Motor Power (HP)
       1.7 2.4
0.25 0.37
0.33 0.5
For Normal Duty applications, use Heavy Duty ratings.
  1
5.6
Max Cont.Current (A)
1.1
Heavy Duty Motor Power (kW)
0.25 0.37 0.55 0.75 0.37 0.55 0.75 1.1 1.5 2.2 3
4 5.5 7.5 11 15 18.5 22 30 37 45 55 45 55
1.5
Motor Power (HP)
0.33 0.5 0.75 1 0.5 0.75 1 1.5 2 3 3 5 7.5 10 15 20 25 30 40 50 60 75 60 75
   DRIVES & STARTERS
           Order Code Supply Phases
Cx00-012 00017A 1 Cx00-012 00024A 1 Cx00-012 00033A 1 Cx00-012 00042A 1 Cx00-022 00024A 1/3 Cx00-022 00033A 1/3 Cx00-022 00042A 1/3 Cx00-022 00056A 1/3 Cx00-022 00075A 1/3 Cx00-032 00100A 1/3 Cx00-042 00133A 1/3 Cx00-042 00176A 3 Cx00-052 00250A 3 Cx00-062 00330A 3 Cx00-062 00440A 3 Cx00-072 00610A 3 Cx00-072 00750A 3 Cx00-072 00830A 3 Cx00-082 01160A 3 Cx00-082 01320A 3 Cx00-092 01760A 3 Cx00-092 02190A 3 Cx00-092 01760E 3 Cx00-092 01760E 3
12 www.controltechniques.com
Max Cont.Current (A)
Normal Duty Motor Power (kW)
Motor Power (HP)
                                                                                                                                                                                    78