Page 66 - Lockwell Industrial Catalogue
P. 66

                     STARTER-CONTROLLER FOR 3-PHASE MOTORS
 TeSys GV7-R
• Control by rocker lever
• Versions from 12 to 220 amps
• Can be operated directly or via external operator
• Can discriminate between types of fault using relevant accessories
    TeSys U
  Toggle Operator
Standard Power Rating
36kA Icu at 415volts
36kA Icu at 415volts
36kA Icu at 415volts
36kA Icu at 415volts
35kA Icu at 415volts
35kA Icu at 415volts
70kA Icu at 415volts
70kA Icu at 415volts
70kA Icu at 415volts
70kA Icu at 415volts
70kA Icu at 415volts
70kA Icu at 415volts
Thermal Trip Setting
25 to 40 amps thermal trip setting
30 to 50 amps thermal trip setting
48 to 80 amps thermal trip setting
60 to 100 amps thermal trip setting
90 to 150 amps thermal trip setting
132 to 220 amps thermal trip setting
25 to 40 amps thermal trip setting
30 to 50 amps thermal trip setting
48 to 80 amps thermal trip setting
60 to 100 amps thermal trip setting
90 to 150 amps thermal trip setting
132 to 220 amps thermal trip setting
Part No.
GV7RE40
GV7RE50
GV7RE80
GV7RE100
GV7RE150
GV7RE220
GV7RS40
GV7RS50
GV7RS80
GV7RS100
GV7RS150
GV7RS220
              TeSys D
• Plate mounted prebuilt star delta starters
• Very compact design
• Protection needs to be provided by a separate thermal overload relay
   • Disconnection, power switching, overload and short circuit protection in one very compact unit
• Total Co-ordination’ - meaning after a short circuit fault the starter can be put back in service immediately - guaranteed no welding of its contacts
• Plug in overload control module can be changed in seconds
• Only45mmwideincludingthereversingoption
• Modular system that can be upgraded when needed
• N.B. Select a DOL or Reversing power base plus the relevant
control module to suit. Additional functionality can be added using a variety of plug in auxiliary and / or function modules.
 Plate Mounted
Operational Current
11 kW at 400 volts
11 kW at 400 volts
11 kW at 400 volts
11 kW at 400 volts
18.5 kW at 400 volts
18.5 kW at 400 volts
18.5 kW at 400 volts
25 kW at 400 volts
25 kW at 400 volts
25 kW at 400 volts
Description:
110 volt AC coil 50 /
415 volt AC coil 50 /
230 volt AC coil 50 /
240 volt AC coil 50 /
110 volt AC coil 50 /
415 volt AC coil 50 /
240 volt AC coil 50 /
110 volt AC coil 50 /
415 volt AC coil 50 /
240 volt AC coil 50 /
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Part No.
LC3D12AF7
LC3D12AN7
LC3D12AP7
LC3D12AU7
LC3D18AF7
LC3D18AN7
LC3D18AU7
LC3D32AF7
LC3D32AN7
LC3D32AU7
  Reversing Power Base
Function characteristics
Pre- assembled 12 amp reversing starter controller power base
Pre- assembled 12 amp reversing starter controller power base
Pre- assembled 32 amp reversing starter controller power base
Pre- assembled 32 amp reversing starter controller power base
  Description
24 volts DC control
110...240 volts AC/DC control
24 volts DC control
110...240 volts AC/DC control
Part No.
LU2B12BL
LU2B12FU
LU2B32BL
LU2B32FU
              Non - Reversing Power Base
 Rail Mounted
Operational Current Description Part No.
Function characteristics
12 amp power base with fixed auxillary connections
32 amp power base with fixed auxillary connections
Maximum Motor Power
5.5 kW
7.5 kW
Part No.
LUB12
LUB32
   11 kW at 400 volts 110 volt AC coil 50 / 60 Hz LC3D120AF7
   66
CONTROL
   64   65   66   67   68