Page 64 - Lockwell Industrial Catalogue
P. 64

                     THERMAL MAGNETIC CIRCUIT BREAKER FOR 3 PHASE TRANSFORMERS
 Rotary Handle - Manual Motor Start
    Thermal setting range
0.16 to 0.25 amps thermal setting range
0.25 to 0.4 amps thermal setting range
0.4 to 0.63 amps thermal setting range
0.63 to 1 amps thermal setting range
1 to 1.6 amps thermal setting range
1.6 to 2.5 amps thermal setting range
2.5 to 4 amps thermal setting range
4 to 6.3 amps thermal setting range
6 to 10 amps thermal setting range
9 to 14 amps thermal setting range
13 to 18 amps thermal setting range
17 to 23 amps thermal setting range
20 to 25 amps thermal setting range
24 to 32 amps thermal setting range
Magnetic trip current
2.4 amps
5 amps
8 amps
13 amps
22.5 amps
33.5 amps
51 amps
78 amps
138 amps
170 amps
223 amps
327 amps
327 amps
416 amps
Part No.
GV2P02
GV2P03
GV2P04
GV2P05
GV2P06
GV2P07
GV2P08
GV2P10
GV2P14
GV2P16
GV2P20
GV2P21
GV2P22
GV2P32
TeSys GV2-RT
              • For the protection of primaries of 3 phase transformers
• Common accessories to GV2ME range
• Control by rocker lever
      TeSys GV2-L, GV2-LE
• Magneticonlyprotection
• Padlockable in the off position for
security and safety to personnel
• Common auxiliaries across all ranges reduces stock holding
• Type 2 co-ordination with TeSys D contactors and LRD overloads
• Rotary or toggle operator
Toggle Operator
  Thermal Trip Setting
0.25 to 4 amps
0.63 to 1 amps
1 to 1.6 amps
1.6 to 2.5 amps
2.5 to 4 amps
4 to 6.3 amps
6 to 10 amps
9 to 14 amps
13 to 18 amps
Magnetic Trip Current
8 amps
22 amps
33 amps
51 amps
78 amps
138 amps
200 amps
280 amps
400 amps
Part No.
GV2RT03
GV2RT05
GV2RT06
GV2RT07
GV2RT08
GV2RT10
GV2RT14
GV2RT16
GV2RT20
            Rotary Handle
 Magnetic Protection Rating
1 amp
1.6 amp
2.5 amp
4 amp
6.3 amp
10 amp
14 amp
18 amp
25 amp
32 amp
Tripping Current (Id+/- 20%)
13 amp
22.5 amp
33.5 amp
51 amp
78 amp
138 amp
170 amp
223 amp
327 amp
416 amp
Part No.
GV2L05
GV2L06
GV2L07
GV2L08
GV2L10
GV2L14
GV2L16
GV2L20
GV2L22
GV2L32
GV2 Range Accessories
• Accessories for the GV2,GV3, and GV7 offers
• A rich variety of options for any application
• Common accessories up to 65 amps reduce spares required
       Busbar Accessories
  Description
Protective end cover
Current limiter
Power combination block
Power combination block
External handle kit for GV2P
Terminal block to supply one or more GV2 breakers
Terminal block to supply one or more GV2 breakers
Set of 3 pole 63 amp busbars
Set of 3 pole 63 amp busbars
Set of 3 pole 63 amp busbars
Set of 3 pole 63 amp busbars
Set of 3 pole 63 amp busbars
Set of 3 pole 63 amp busbars
Set of 3 pole 63 amp busbars
Characteristics
For unused bus bar outlets
-
Connects contactor to breaker
Connects contactor to breaker
Red/Yellow handle
Connection from the top
Connection from the bottom
45mm pitch
45mm pitch
45mm pitch
54mm pitch
54mm pitch
54mm pitch
54mm pitch
Characteristics
-
Fits on top of GV2P or GV2ME
Fits between GV2 & LC1K or LP1K
Fits between GV2 & LC1D09 to D38
IP54
Mounted anywhere along the busbar
Mounted on left hand side of busbar
2 tap offs
3 tap offs
4 tap offs
2 tap offs
3 tap offs
4 tap offs
5 tap offs
Part No.
GV1G10
GV1L3
GV2AF01
GV2AF3
GV2APN02
GV1G09
GV2G05
GV2G245
GV2G345
GV2G445
GV2G254
GV2G354
GV2G454
GV2G554
         Toggle Operator
 Magnetic Protection Rating
1 amp
4 amp
6.3 amp
10 amp
14 amp
18 amp
25 amp
32 amp
Tripping Current (Id+/- 20%)
13 amp
51 amp
78 amp
138 amp
170 amp
223 amp
327 amp
416 amp
Part No.
GV2LE05
GV2LE08
GV2LE10
GV2LE14
GV2LE16
GV2LE20
GV2LE22
GV2LE32
                   64
CONTROL
   62   63   64   65   66