Page 322 - Lockwell Industrial Catalogue
P. 322

  CLAMP METERS IR THERMOMETERS
  Fluke 370 Series Clamp Meters
Unprecedented measurement flexibility. The Fluke 370 FC Series clamp meters offer advanced troubleshotting performance plus Fluke Connect features to log and transmit data wirelessly. The Fluke 370 Series have a large backlit display, trye-rms standard, CAT IV safety rating and a durably constructed body. Additionally, the 376 FC, 375 FC and 374 FC are compatible with the iFlex® Flexible Current Probe that measure up to 2500 A AC.
Fluke 64 MAX IR Thermometer
     The Fluke 64 MAX thermometer has the precision you need to do your job accurately and will not break the budget. Designed and tested to survive a 3 meter drop, you can count on this lightweight, compact infrared thermometer to work when you need it to work – even in the harshest environments and when you’re not able to be there.
• Precise laser technology for more accurate and repeatable measurements
• Temperature accuracy of up to ± 1↓ or ± 1% of reading
whichever is greater with 20:1 distance to spot ratio
• Flashlight and large, easy-to-read backlit LCD display
for easy viewing even in dark environment
• IP54 rated for extra protection against airborne contaminants
• Get your tool to work when you can’t - set time and desired interval between
measurements and Auto Capture will capture spot temperatures unattended
• 99 data point logging
• 30 hour battery life so your tool can perform as long as you need it to
• Displays the minimum, maximum or average temperature,
or the difference between two measurements
• Hi and Lo alarms for rapid display of measurements outside set limits
• Small and lightweight design fits easily into your tool box
• Powered by one AA alkaline battery
 Jaw opening
Max wire size
Current range ac rms
Accuracy ac current (50/60 Hz)
AC response
Current range dc
Accuracy dc current
Voltage range ac
Accuracy ac voltage
Voltage range dc
Accuracy dc voltage
Resistance range
Frequency measure- ment range
Safety rating
Fluke Connect® compatible
Fluke 376 FC
34 mm (1.33 in)
400 mm2
0 to 999.9 A (2500 A with iFlex)
2 % ± 5 counts
True-rms
0 to 999.0 A
2 % ± 5 counts
0 to 1000 V
1.5 % ± 5 counts
0 to 1000 V
1 % ± 5 counts
0 to 60 kΩ
500 Hz
CAT III 1000 V CAT IV 600 V
↓
Fluke 375 FC
34 mm (1.33 in)
400 mm2
0 to 600.0 A (2500 A with iFlex)
2 % ± 5 counts
True-rms
0 to 600.0 A
2 % ± 5 counts
0 to 1000 V
1.5 % ± 5 counts
0 to 1000 V
1 % ± 5 counts
0 to 6000 Ω
500 Hz
CAT III 1000 V CAT IV 600 V
↓
Fluke 374 FC
34 mm (1.33 in)
400 mm2
0 to 600.0 A (2500 A with iFlex)
2 % ± 5 counts
True-rms
0 to 600.0 A
2 % ± 5 counts
0 to 1000 V
1.5 % ± 5 counts
0 to 1000 V
1 % ± 5 counts
0 to 6000 Ω
-
CAT III 1000 V CAT IV 600 V
↓
Fluke 373
32 mm (1.26 in)
400 mm2
0 to 600.0 A
2 % ± 5 counts
True-rms
-
-
0 to 600.0 V
1 % ± 5 counts
0 to 600.0 V
1 % ± 5 counts
0 to 6000 Ω
-
CAT III 600 V CAT IV 300 V
-
    Specification
Temperature range
Accuracy
Optical resolution
Response time (95 %)
Spectral response
Emissivity
Display resolution
Repeatability (% of reading)
Auto capture
Internal memory
Compliance
Laser safety
Fluke 64 MAX
-30 °C to 600 °C
± 1.0 °C or ± 1.0 % of reading, whichever is greater ± 2.0 °C at -10 °C to 0 °C
± 3.0 °C at -30 °C to -10 °C
20 : 1 (calculated at 90 % energy)
< 500 ms (95% of reading)
8 to 14 microns
0.10 to 1.00
0.1 °C
± 0.5 % of reading or ± 0.5 °C (whichever is greater)
Set time and interval to capture up to 99 measurements
99 data point logging capability
IEC 61010-1: Pollution Class 2
IEC 60825-1 Class 2, 650 nm, < 1 mW
                        Ingress protection rating
IP 54 per IEC 60529