Page 320 - Lockwell Industrial Catalogue
P. 320

    Fluke 1660 Series Multifunction Installation Testers
   Installation testing that protects appliances, wireless shares data.
The new Fluke 1660 Series Installation Testers are the only installation testers that help prevent damage to connected appliances at insulation tests, and also allow users to send test results wirelessly via smartphone directly from the field.
Features and benefits
• Insulation PreTestTM - Stops insulation test when a connected appliance is detected
• Fluke CloudTM storage - flexible and secure data storage from the field
• Auto test - does 5 required installation tests in one sequence,
including selectable Type A, AC and RCD Auto Test
• Heavy duty, single input line cord, guards against failures in the field
• Z Max memory function for loop/line test (1663 & 1664 FC)
• Safety rating (IEC/EN 61010): CAT III 500 V, CAT IV 300 V
Specification 1662 1663
Insulation-PreTestTM safety function
Insulation at L-N, L-PE, N-PE inputs
Auto test sequence
Loop and line resistance - mΩ resolution
Continuity at L-N, L-PE, N-PE inputs ↓
Test smooth dc sensitive RCDs (type B/B+) ↓
Earth resistance ↓
Voltage trms (AC and DC) and frequency ↓ ↓
Wiring polarity checker, detects broked PE and N wires ↓ ↓
Insulation resistance ↓ ↓
Continuity and resistance ↓ ↓
Measure motor windings with continuity test (@ 10 mA) ↓ ↓
Loops and line resistance ↓ ↓
Prospective earth fault current (PEFC/IK) ↓ ↓
Prospective short-circuit current (PSC/IK) ↓ ↓
RCD trip time ↓ ↓
RCD trip current (ramp test) ↓ ↓
Measures trip time and current for RCD type A and AC in ↓ ↓ one test
Automatic RCD test sequence ↓ ↓
Phase sequence test ↓ ↓
1664 FC
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
Fluke VoltAlertTM Family
The next generation VoltAlertTM AC non-contact voltage testers from Fluke are easy to use. Electricians, maintenance, service and safety personnel, and homeowners can quickly test for energized currents in the workplace or at home. Certified up to CAT IV 1000 V.
 Fluke 1AC II VoltAlertTM
• Continually tests battery and its circuit integrity with a periodic double flash visual indication
• Fits in shirt pocket for convenience
• Outer surfaces are nonconductive for safety
• Detects voltage without metallic contact
• Highest safety rating: CAT IV 1000 V
 Voltage range
Audible alert
Flashlight
On/Off
Safety Rating
1AC II
90 V AC to 1000 V AC
↓
↓
CAT IV 1000 V
LVD2
90 V AC to 600 V AC
↓
↓
↓
CAT IV 600 V
     Fluke T6 Electrical Testers with FieldSense Technology
Measure voltage...without test leads Measure voltage up to 1000 V ac through the open fork, without test lead contact to live voltage.+ Without opening covers or removing wire nuts. On wires up to AWG 4/0 (120 mm2 ), carrying as much as 200 A. It will change your job. Safer. Faster. Easier. + Requires capacitive path to ground, provided through user in most applications. Ground connection via test
lead may be required in some situations.
Product Highlights
• FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage+
• Simultaneous voltage and current display (T6-1000)—shows all power supply measurements at a glance for efficient troubleshooting
• 1 to 1000 V ac or dc (T6-1000); 600 V ac or dc (T6-600)
• 0.1 to 200 A ac
• Resistance 1 Ω to 100 kΩ (T6-1000), 1 Ω to 2 kΩ (T6-600)
• Frequency measurement 45 Hz to 66 Hz (T6-1000)
• Works with wires up to AWG 4/0 (120 mm2) with a17.8 mm jaw opening.
• HOLD button temporarily freezes the reading for easy viewing
• Easy to read display with backlight
• Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
            Function
FieldSense AC voltage
FieldSense AC current
FieldSense frequency (Hz)
Volts AC
Volts DC
Resistance
Resistance
Resistance
Requires test leads
No
No
No
Yes
Yes
Yes
Yes
Yes
T6-600 Range
600 V
200.0 A
-
600 V
600 V
2000 Ω
-
-
T6-1000 Range
1000 V
200.0 A
45 Hz - 66 Hz
1000 V
1000 V
2000 Ω
20.00 kΩ
100.0 kΩ
Resolution
1 V
0.1 A
1 Hz
1 V
1 V
1 Ω
0.01 kΩ
0.1 kΩ
Accuracy
±(3 % + 3 counts) [2] [3] 45 Hz - 66 Hz
±(3 % + 3 counts) 45 Hz - 66 Hz
±(1 % + 2 counts) [3]
±(1.5 % + 2 counts) 45 Hz - 66 Hz
±(1 % + 2 counts)
±(1 % + 2 counts)
±(1 % + 2 counts)
±(1 % + 2 counts)
                  Z Max memory
Memory
IR-USB and BLE interface (when used with optional Fluke DMS and FVF software)
↓ ↓
↓↓↓
IR-USB IR-USB IR-USB/BLE
  Safety rating
-
CAT III 600 V
CAT III 1000 V CAT IV 600 V
    320
TEST INSTRUMENTS
   318   319   320   321   322