Page 319 - Lockwell Industrial Catalogue
P. 319

 THERMAL IMAGERS ELECTRICAL PRODUCTS
  Fluke Performance Series
Easy-to-use frontline troubleshooting. Easily see potential problems with precisely blended IR and visual images - with a 5MP visual camera, up to 260 x 195 resolution, and a large 3.5 inch LCD. Get precise focus as close as 15 cm (6 in) with manual focus.
• Get the context of the visual and infrared details all in one precisely blended or picture-in-picture image with IR-Fusion® technology1
• Reduce the amount of time it takes to get an in focus image with manual or fixed focus options
• Make decisions in real time - wirelessly sync images from your camera, create and email reports all with your smart phone and the Fluke Connect® App.
• Digitally document critical information with your infrared image using IR-PhotoNotesTM or voice annotation2
• 1IR-Fusion® and picture-in-picture mode execution varies by model
• 2Varies by model
Fluke Voltage and Continuity Testers
Rugged, high-quality testers for fast test results the way you need them. All electricians need a two-pole tester. Experiences professionals know that they can - and should - trust their job, their reputation and even their personal safety to Fluke electrical test tools. Our new family of Two-Pole Voltage Testers is
no exception. Built with state-of-the art measurement and safety technology, these testers offer everything you expect from Fluke, and a little bit more.
• Rugged, high-quality construction is built to last. This includes a heavy duty molded case, a thicker cord with wear indicator, sturdy battery case, and well fitting and durable probe protector
• Fast results the way you need them, with large, easy-to-
use buttons, bright backlights, and clear audible and physical indicators designed for work in any situation
• Enhanced ergonomic design feels good in your hand, is easy to use (even with gloves on) and quick, secure probe docking
• Compliant with regulations HSE GS 38 (tip caps) and IEC EN 61243-3:2014
   Specification
Voltage AC/DC
Continuity
Frequency
Phase rotation
Resistance measurement
Response time (LED ladders)
200 kΩ input impedance
7 kΩ input impedance (with load buttons pressed)
Safety rating
IP rating
T90
12 V - 690 V
0 - 400 kΩ
0 - 60 Hz
-
-
< 0.1 s
Current draw 3.5 mA @ 690 V Current draw 1.15 mA @ 230 V
-
Cat II 690 V Cat III 600 V
IP54
T130
6 V - 690 V
0 - 400 kΩ
0 - 400 Hz
100 V - 690 V
-
< 0.1 s
Current draw 3.5 mA @ 690 V Current draw 1.15 mA @ 230 V
Current draw 30 mA @ 230 V
Cat III 690 V Cat IV 600 V
IP64
T150
6 V - 690 V
0 - 400 kΩ
0 - 400 Hz
100 V - 690 V
Up to 1999 Ω
< 0.1 s
Current draw 3.5 mA @ 690 V Current draw 1.15 mA @ 230 V
Current draw 30 mA @ 230 V
Cat III 690 V Cat IV 600 V
IP64
      Detector resolution
Field of view
Focus system
IR Fusion
Thermal sensitivity
Temperature measurement range
Frame rate
Documentation features
Alarms
TiS20
120 x 90
35.7 °H x 26.8 °V
Fixed Focus
3 presets (0 %, 50 %, 100 %)
≤ 0.10 °C at 30 °C target temp (100 mK)
-20 °C to +350 °C (–4 °F to 662 °F)
9 Hz
-
-
TiS45
160 x 120
35.7 °H x 26.8 °V
Manual Focus
5 presets (0 %, 25 %, 50 %, 75 %, 100 %)
≤ 0.09 °C at 30 °C target temp (90 mK)
-20 °C to +350 °C (–4 °F to 662 °F)
30 Hz or 9 Hz
Voice annotation
High temperature, low temperature, time lapse - auto image capture
TiS65
260 x 195
35.7 °H x 26.8 °V
Manual Focus
5 presets (0 %, 25 %, 50 %, 75 %, 100 %)
≤ 0.08 °C at 30 °C target temp (80 mK)
-20 °C to +550 °C (–4 °F to 1022 °F)
30 Hz or 9 Hz
IR-PhotoNotesTM (3 images), voice annotation
High temperature, low temperature, time lapse - auto image capture, and isotherms (within range)
               Can't see what you need? Our experts can help!
319
 TEST INSTRUMENTS
   317   318   319   320   321