Page 20 - Lockwell Industrial Catalogue
P. 20

 MS116 manual motor starters
0.10 to 32 A – with thermal and electromagnetic protection
MS116-16
MS116-25
MS116-0.16-HKF1-11
MS116-32-HKF1-11
Ordering details
Rated Setting operational range power
400 V
AC-3
kW A
Short-circuit breaking capacity ICS at 400 V AC
Rated instanta- neous short-cir- cuit current setting li
Type
MS116-0.16 MS116-0.25 MS116-0.4 MS116-0.63 MS116-1.0 MS116-1.6 MS116-2.5 MS116-4.0 MS116-6.3 MS116-10
MS116-12
MS116-16
MS116-20
MS116-25
MS116-32 MS116-0.16-HKF1-11 MS116-0.25-HKF1-11 MS116-0.4-HKF1-11 MS116-0.63-HKF1-11 MS116-1.0-HKF1-11 MS116-1.6-HKF1-11 MS116-2.5-HKF1-11 MS116-4.0-HKF1-11 MS116-6.3-HKF1-11 MS116-10.0-HKF1-11 MS116-12.0-HKF1-11 MS116-16.0-HKF1-11 MS116-20-HKF1-11 MS116-25-HKF1-11 MS116-32-HKF1-11
Order code
1SAM250000R1001 1SAM250000R1002 1SAM250000R1003 1SAM250000R1004 1SAM250000R1005 1SAM250000R1006 1SAM250000R1007 1SAM250000R1008 1SAM250000R1009 1SAM250000R1010 1SAM250000R1012 1SAM250000R1011 1SAM250000R1013 1SAM250000R1014 1SAM250000R1015 1SAM250005R1001 1SAM250005R1002 1SAM250005R1003 1SAM250005R1004 1SAM250005R1005 1SAM250005R1006 1SAM250005R1007 1SAM250005R1008 1SAM250005R1009 1SAM250005R1010 1SAM250005R1012 1SAM250005R1011 1SAM250005R1013 1SAM250005R1014 1SAM250005R1015
Weight (1 pce)
kg
0.225 0.225 0.225 0.225 0.225 0.265 0.265 0.265 0.265 0.265 0.265 0.265 0.310 0.310 0.310 0.240 0.240 0.240 0.240 0.240 0.280 0.280 0.280 0.280 0.280 0.280 0.280 0.326 0.326 0.326
20
Description
MS116 is a compact and economic range for motor protection up to 15 kW (400 V) / 32 A in width
of 45 mm. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory. These are suitable throughout the MS116/MS132/MS165-range.
0.03 2) 0.06 0.09 0.18 0.25 0.55 0.75 1.50 2.20 4.00 5.50 7.50 7.50 11.0 15.0 0.03 2) 0.06 0.09 0.18 0.25 0.55 0.75 1.50 2.20 4.00 5.50 7.50 7.50 11.0 15.0
0.10 ... 0.16 50 0.16 ... 0.25 50 0.25 ... 0.40 50 0.40 ... 0.63 50 0.63 ... 1.00 50 1.00 ... 1.60 50 1.60 ... 2.50 50 2.50 ... 4.00 50 4.00 ... 6.30 50 6.30 ... 10.0 50 8.00 ... 12.0 25 10.0 ... 16.0 16 16.0 ... 20.0 10 20.0 ... 25.0 10 25.0 ... 32.0 10 0.10 ... 0.16 50 0.16 ... 0.25 50 0.25 ... 0.40 50 0.40 ... 0.63 50 0.63 ... 1.00 50 1.00 ... 1.60 50 1.60 ... 2.50 50 2.50 ... 4.00 50 4.00 ... 6.30 50 6.30 ... 10.0 50 8.00 ... 12.0 25 10.0 ... 16.0 16 16.0 ... 20.0 10 20.0 ... 25.0 10 25.0 ... 32.0 10
2.00 1) 3.10 1) 5.00 1) 7.90 1) 12.5 1) 20.0 1) 31.3 1) 50.0 78.8 150 180 240 300 375 480 2.00 1) 3.10 1) 5.00 1) 7.90 1) 12.5 1) 20.0 1) 31.3 1) 50.0 78.8 150 180 240 300 375 480
kAA
Note: Manual motor starters should always be selected so that the actual motor current is within the setting range. 1) The data is valid for products, produced after week 34, 2014.
2) 690 V
CONTROL
2CDC241012F0011 2CDC241013F0011 2CDC241001F0011 2CDC241010F0011






























































   18   19   20   21   22