  SAFETY RELAYS AND SWITCHES
 S3000 standard
High specification laser scanner
The S3000 Standard version laser scanner is a great value unit offering one protective field and two warning fields. It does not include any digital inputs for protection field switching.
It can be used for horizontal and vertical safeguarding of hazardous points of operation, dangerous areas, and access in compliance with Type 3 of IEC/EN 61496-3. Improved detection capabilities also make the S3000 suitable for hand, limb and
body detection.
Features
• Type 3 (IEC 61496), PLd (EN ISO 13849), SIL2 (IEC 62061)
• SingleFieldSetMonitoring
• Configuration memory integrated in the system plug
• Interface (EFI) for reliable SICK device communication
• Selectable resolution for hand, leg or body detection
• Simultaneous monitoring of up to 4 protective fields with SICK Flexi Soft
• Contour as reference for vertical applications
• Integratedexternaldevicemonitoring(EDM) Technical specification
• Protective field range Up to 7m
• Field range 49m
• Scanning angle 190o
• Responsetime60mS
• Object resolution 30/40/50/70/150mm
• OSSD’s with short circuit protection and cross circuit monitored
• ResetinputIntegrated
• EDM input Integrated
• Type of connection System plug
• ProtectionIP65
• Operating temperature -10 to +50oC
• Dimensions h185 x w155 x d160mm
  Part number
S30A-4011BA
S30A-6011BA
S30A-7011BA
Protective Field Range
4m
5.5m
7m
Warning field range
49 m (20 m at 20 % reflectivity)
49 m (20 m at 20 % reflectivity)
49 m (20 m at 20 % reflectivity)
Description
Response time
60 ms
60 ms
60 ms
Safety ReLy
The safety relays from the ReLy product family monitor safety functions or safety sensors up to performance level e. The ReLy portfolio is clear and concise. Each
of the four ReLy modules contains everything that a modern safety relay needs. Two contact paths for switching off machines safely. Fast response time of 10 ms for short safety distances. A slim housing for added space in the control cabinet. Versatile diagnostics options for quick and easy troubleshooting. Simply the sensor type to be connected determines which product is the right one to choose.
Features
• Type 4 (IEC 61496), PLe (EN ISO 13849), SIL3 (IEC 62061)
• Two contact paths for switching off machine
• Fastresponsetime
• Plug-interminalsforeasymaintenance
• Slim housing to save space in cabinet
• Diagnostics via LED’s and “application diagnostics output”
• Clearandconciserelayselection
• Simplemountingconcept Technical specification
• 10 mS Response Time
• Switching voltage 10 V DC ... 250 V DC (Enable Current Contacts)
• Switching current 10 mA ... 6 A (Enable Current Contacts)
• Switching voltage 15 V DC ... 30 V DC (Contactor monitoring contacts on RLY-OSSD1
• Switching current 3 mA ... 100 mA (Contactor monitoring contacts on RLY-OSSD1
• HIGH Input Voltage 24 V DC (15 V DC ...30 V DC) - RLY-OSSD1
• HIGH Input Voltage - HIGH 24 V DC (11 V DC ... 30 V DC)
       Recommended accesssories: Part number
2049222
2027171
2027814
6021195
6034574
1085343
2015623
2015624
2015625
7087514
Pre-assembled system plug with 5m cable
re-assembled system plug with 10m cable
Pre-assembled system plug with 20m cable
2m programming cable – serial
2m programming cable – USB
Safety Relay
Mounting bracket kit 1
Mounting bracket kit 2
Mounting bracket kit 3
 - RYL-OSSD2, RLY-EMMS1 & RLY-HAND1 • LOW Input Voltage - 3 V DC ... 5 V DC
   Part number
RLY3-OSSD1
RLY3-OSSD2
RLY3-EMSS1
Selection
For devices with OSSD outputs and integrated reset/EDM functions (E.g. Safety relays, Safety Laser scanners)
For devices with OSSD outputs but without reset/EDM functions (E.g. Basic Safety Light Curtains, RFID Safety switches)
For Dual Channel Equivalent Electromechanical Switches (E.g. Safety limit switches, Interlocks, Emergency Stops)
          Heavy duty mounting bracket
RLY3-HAND1
For 2 Hand Modules as per EN574