Page 138 - Lockwell Industrial Catalogue
P. 138

           SAFETY MODULES/MONITORING
    Multi-Functional Safety Relay Modules
SRB-e-Series
Multi-Functional Safety Relay Modules 22.5mm Housing. The SRB- e402ST is a combination module for 2 safety guards.
          Applications & Functions
•
E-Stop, Guard Monitoring, Pull-Wire E-Stop, Magnetic Safety Sensors, AOPD, 2 Hand Control
 Part number
SRB-e-201ST
SRB-e-201LC
SRB-e-301ST
SRB-e-204ST
SRB-e-402ST
Supply Voltage
24VDC
24VDC
24VAC/DC
24VDC
24VDC
Safety Classification
Ple / SIL3
Ple / SIL3
Ple / SIL3
Ple / SIL3
Ple / SIL4
Output Contacts safe stop 0
2 x non Safe output contacts Semi Conductor
2 x non Safe output contacts Semi Conductor
3 x safety output contacts
2 x non Safe output contacts Semi Conductor
2 x safety output & 2 x non Safe output contacts Semi Conductor
Signal Outputs
1
1
1
4
2
AutoStart or Edge Detection
AutoStart or Edge Detection
AutoStart or Edge Detection
AutoStart or Edge Detection
AutoStart or Edge Detection
RFID TECHNOLOGY
NOTE: Non-Coded versions are available as standard. Versions with I2 are available on request.
Actuators
RSS series
         Part number
RST260-1 RST16-1 RST-U-2
  Safety Sensors
RSS series
       •
2 x P type, short circuit proof safety outputs
Part number
RSS260-D-ST
RSS36-I2-D-ST
Ple Cat4 (ISO1384-1)
Ple Cat4 (ISO1384-1)
Diagnostic
Conventional. 2 x OSSD. 1 x Diagnostic
Conventional. 2 x OSSD. 1 x Diagnostic
Sensing Dis- tance (on/off)
10mm /18mm
10mm /18mm
Direction of Actuation
Side
Side
Supply Voltage
24VDC
24VDC
NOTE: Non-Coded versions are available as standard. Versions with I1 & I2 are available on request.
   NOTE: Non-Coded versions are available as standard. Versions with I2 are available on request.
Actuators
   RSS series
Part number
RST36-1-R
Latching/Non Latching
Latching
  RST36-1
Non-Latching
  138
Safety Sensors
RSS series
Rectangular housing with RFID technolgy. Operating condition identified with 3 x LEDs. 24v.
Applications & Functions
• Latching & Non-Latching options. 2 x P Type short circuit proof safety outputs • ConnectorPlug
• With I2 version, the teach in process can be repeated
Part number
RSS36-l2-D-R-ST
RSS36-D-R-ST
RSS36-I2-D-ST
RSS36-D-ST
Latching/Non Latching
Latching
Latching
Non-Latching
Non-Latching
Safety Classifi- cation
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Ple Cat4 (ISO13849-1)
Ple cat4 (ISO13849-1)
Diagnostic
Conventional. 2 x OSSD. 1 x Diagnostic
Conventional. 2 x OSSD. 1 x Diagnostic
Conventional. 2 x OSSD. 1 x Diagnostic
Conventional. 2 x OSSD. 1 x Diagnostic
Sensing Dis- tance (on/off)
10mm /16mm
10mm /16mm
10mm /16mm
10mm /16mm
Direction of Actuation
Side
Side
Side
Side
 SAFETY